IEEE 841 Severe Duty Motors

HYUNDAI Crown Triton™ Series

Severe Duty Motor | IEEE-841 | Premium Efficiency

RIGID BASE

Hyundai Crown Triton Motors

Severe Duty - IEEE-841

Offer above and beyond severe duty requirements with Hyundai Heavy Industries IEEE-841 Rigid Base motors.

  • 1-250 HP
  • 3600, 1800 and 1200 RPM
  • Single voltage, 460 volt
  • TEFC enclosure
  • IP55 degree of protection
  • Dual rated service factor 1.15 for 40°C / 1.0 for 65°C
  • Class F insulation with Class N varnish
  • Rigid base
  • Full compliance with IEEE-841, version 2009
  • Premium Efficiency
  • Class B temperature rise
  • NEMA design B torque
  • Parker Hannifan ProTech IP66 labyrinth seals on both drive-end and opposite drive-end bearings
  • Inverter duty, 10:1 CT / 1000:1 VT
  • Inverter shield insulation and inverter grade magnet wire meets or exceeds NEMA MG-1 Part 31 for exceptional corona and transient protection
  • IEEE-841 motor test report supplied with each motor
  • Suitable for 50 hz operation with 1.0 service factor
  • CSA Certified for Class I, Division 2, Groups A, B, C, D
  • Three-Phase

C-FACE - RIGID BASE

Hyundai Crown Triton Motors

Severe Duty - IEEE-841

Offer above and beyond severe duty requirements with Hyundai Heavy Industries IEEE-841 C-Face motors. These motors include added features like: epoxy paint, ProTech® IP66 seals on both the drive end and opposite drive end, precision balance, and the lowest vibration spec and best thermal protection in the industry.

  • 1-100 HP
  • 3600 and 1800 RPM
  • Single voltage, 460 volt
  • TEFC enclosure
  • IP55 degree of protection
  • Dual rated service factor 1.15 for 40°C / 1.0 for 65°C
  • Class F insulation with Class N varnish
  • C-face - rigid base
  • Full compliance with IEEE-841, version 2009
  • Premium Efficiency
  • Class B temperature rise
  • NEMA design B torque
  • Parker Hannifan ProTech IP66 labyrinth seals on both drive-end and opposite drive-end bearings
  • Inverter duty, 10:1 CT / 1000:1 VT
  • Inverter shield insulation and inverter grade magnet wire meets or exceeds NEMA MG-1 Part 31 for exceptional corona and transient protection
  • IEEE-841 motor test report supplied with each motor
  • Suitable for 50 hz operation with 1.0 service factor
  • CSA Certified for Class I, Division 2, Groups A, B, C, D
  • Hyundai Crown Triton Series
  • Three-Phase

About Environmental Solutions

Since 1995, Environmental Solutions has been helping businesses, like yours, improve their workplace efficiency and air quality. We represent a number of best in class brands, including Worldwide Electric Corp. (worldwide distributor of Hyundai Electric Motors and Drives), Donaldson Torit, and others. We offer fast, expert service at highly competitive prices and would welcome the opportunity to earn your business.

CALL TOLL FREE 1-866-438-7891